blob: 317cd2f2d74536163a8828d7d1e3755e079b6deb [file] [log] [blame]
/*
* Copyright (c) 2000 World Wide Web Consortium,
* (Massachusetts Institute of Technology, Institut National de
* Recherche en Informatique et en Automatique, Keio University). All
* Rights Reserved. This program is distributed under the W3C's Software
* Intellectual Property License. This program is distributed in the
* hope that it will be useful, but WITHOUT ANY WARRANTY; without even
* the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR
* PURPOSE. See W3C License http://www.w3.org/Consortium/Legal/ for more
* details.
*
* Difference to the original copy of this file:
* 1) ADD public static final short FILL_AUTO = 2;
* 2) ADD public short getFillDefault();
* 3) AND public void setFillDefault(short fillDefault)
* throws DOMException;
*/
package org.w3c.dom.smil;
import org.w3c.dom.DOMException;
/**
* This interface defines the set of timing attributes that are common to all
* timed elements.
*/
public interface ElementTime {
/**
* The desired value (as a list of times) of the begin instant of this
* node.
* @exception DOMException
* NO_MODIFICATION_ALLOWED_ERR: Raised if this attribute is readonly.
*/
public TimeList getBegin();
public void setBegin(TimeList begin)
throws DOMException;
/**
* The list of active ends for this node.
* @exception DOMException
* NO_MODIFICATION_ALLOWED_ERR: Raised if this attribute is readonly.
*/
public TimeList getEnd();
public void setEnd(TimeList end)
throws DOMException;
/**
* The desired simple duration value of this node in seconds. Negative
* value means "indefinite".
* @exception DOMException
* NO_MODIFICATION_ALLOWED_ERR: Raised if this attribute is readonly.
*/
public float getDur();
public void setDur(float dur)
throws DOMException;
// restartTypes
public static final short RESTART_ALWAYS = 0;
public static final short RESTART_NEVER = 1;
public static final short RESTART_WHEN_NOT_ACTIVE = 2;
/**
* A code representing the value of the restart attribute, as defined
* above. Default value is <code>RESTART_ALWAYS</code> .
* @exception DOMException
* NO_MODIFICATION_ALLOWED_ERR: Raised if this attribute is readonly.
*/
public short getRestart();
public void setRestart(short restart)
throws DOMException;
// fillTypes
public static final short FILL_REMOVE = 0;
public static final short FILL_FREEZE = 1;
public static final short FILL_AUTO = 2;
/**
* A code representing the value of the fill attribute, as defined
* above. Default value is <code>FILL_REMOVE</code> .
* @exception DOMException
* NO_MODIFICATION_ALLOWED_ERR: Raised if this attribute is readonly.
*/
public short getFill();
public void setFill(short fill)
throws DOMException;
/**
* The repeatCount attribute causes the element to play repeatedly
* (loop) for the specified number of times. A negative value repeat the
* element indefinitely. Default value is 0 (unspecified).
* @exception DOMException
* NO_MODIFICATION_ALLOWED_ERR: Raised if this attribute is readonly.
*/
public float getRepeatCount();
public void setRepeatCount(float repeatCount)
throws DOMException;
/**
* The repeatDur causes the element to play repeatedly (loop) for the
* specified duration in milliseconds. Negative means "indefinite".
* @exception DOMException
* NO_MODIFICATION_ALLOWED_ERR: Raised if this attribute is readonly.
*/
public float getRepeatDur();
public void setRepeatDur(float repeatDur)
throws DOMException;
/**
* Causes this element to begin the local timeline (subject to sync
* constraints).
* @return <code>true</code> if the method call was successful and the
* element was begun. <code>false</code> if the method call failed.
* Possible reasons for failure include: The element doesn't support
* the <code>beginElement</code> method. (the <code>beginEvent</code>
* attribute is not set to <code>"undefinite"</code> ) The element is
* already active and can't be restart when it is active. (the
* <code>restart</code> attribute is set to <code>"whenNotActive"</code>
* ) The element is active or has been active and can't be restart.
* (the <code>restart</code> attribute is set to <code>"never"</code> ).
*
*/
public boolean beginElement();
/**
* Causes this element to end the local timeline (subject to sync
* constraints).
* @return <code>true</code> if the method call was successful and the
* element was endeed. <code>false</code> if method call failed.
* Possible reasons for failure include: The element doesn't support
* the <code>endElement</code> method. (the <code>endEvent</code>
* attribute is not set to <code>"undefinite"</code> ) The element is
* not active.
*/
public boolean endElement();
/**
* Causes this element to pause the local timeline (subject to sync
* constraints).
*/
public void pauseElement();
/**
* Causes this element to resume a paused local timeline.
*/
public void resumeElement();
/**
* Seeks this element to the specified point on the local timeline
* (subject to sync constraints). If this is a timeline, this must seek
* the entire timeline (i.e. propagate to all timeChildren).
* @param seekTo The desired position on the local timeline in
* milliseconds.
*/
public void seekElement(float seekTo);
public short getFillDefault();
public void setFillDefault(short fillDefault)
throws DOMException;
}