config QCOM_TSENS
tristate "Qualcomm TSENS Temperature Alarm"
depends on THERMAL
depends on QCOM_QFPROM
depends on ARCH_QCOM || COMPILE_TEST
help
This enables the thermal sysfs driver for the TSENS device. It shows
up in Sysfs as a thermal zone with multiple trip points. Disabling the
thermal zone device via the mode file results in disabling the sensor.
Also able to set threshold temperature for both hot and cold and update
when a threshold is reached.
config QTI_THERMAL_LIMITS_DCVS
bool "QTI LMH DCVS Driver"
depends on THERMAL_OF
depends on CPU_THERMAL
help
This enables the driver for Limits Management Hardware - DCVS block
for the application processors. The h/w block that is available for
each cluster can be used to perform quick thermal mitigations by
tracking temperatures of the CPUs and taking thermal action in the
hardware without s/w intervention.
config QTI_VIRTUAL_SENSOR
bool "QTI Virtual Sensor driver"
depends on THERMAL_OF
help
This driver has the information about the virtual sensors used by
QTI chipset's and registers the virtual sensors to a thermal zone.
The virtual sensor information includes the underlying thermal
sensors to query for temperature and the aggregation logic to
determine the virtual sensor temperature.
config QTI_AOP_REG_COOLING_DEVICE
bool "QTI AOP Regulator cooling device"
depends on THERMAL_OF && MSM_QMP
help
This enables the AOP based Regulator cooling device. This cooling
device will be used by QTI chipset to place a floor voltage
restriction at low temperatures. The cooling device will message
the AOP using mail box to establish the floor voltage.
config QTI_QMI_COOLING_DEVICE
bool "QTI QMI cooling devices"
depends on QCOM_QMI_HELPERS && THERMAL_OF
help
This enables the QTI remote subsystem cooling devices. These cooling
devices will be used by QTI chipset to place various remote
subsystem mitigations like remote processor passive mitigation,
remote subsystem voltage restriction at low temperatures etc.
The QMI cooling device will interface with remote subsystem
using QTI QMI interface.
config QTI_QMI_SENSOR
bool "QTI QMI sensor driver"
depends on QCOM_QMI_HELPERS && THERMAL_OF
help
This enables to list the QTI remote subsystem temperature sensors.
This driver can read the temperature of the remote sensor.
These sensors can take thresholds and notify the thermal
framework when the threshold is reached.
config REGULATOR_COOLING_DEVICE
bool "Regulator voltage floor cooling device"
depends on REGULATOR && THERMAL_OF
help
This implements a mitigation device to place a minimum voltage floor
on a particular regulator. This mitigation device will be used by low
temperature reliability rules to mitigate a regulator at nominal
voltage.
If you want this support, you should say Y here.
config QTI_BCL_PMIC5
bool "BCL driver for BCL peripherals in PMIC5"
depends on SPMI && THERMAL_OF
help
Say Y here to enable this BCL driver for PMIC5. This driver
provides routines to configure and monitor the BCL
PMIC peripheral. This driver registers the battery current and
voltage sensors with the thermal core framework and can take
threshold input and notify the thermal core when the threshold is
reached.
config MSM_BCL_PERIPHERAL_CTL
bool "BCL driver to control the PMIC BCL peripheral"
depends on SPMI && THERMAL_OF
help
Say Y here to enable this BCL PMIC peripheral driver. This driver
provides routines to configure and monitor the BCL
PMIC peripheral. This driver registers the battery current and
voltage sensors with the thermal core framework and can take
threshold input and notify the thermal core when the threshold is
reached.
config QTI_BCL_SOC_DRIVER
bool "QTI Battery state of charge sensor driver"
depends on THERMAL_OF
help
This driver registers battery state of charge as a sensor with
thermal zone. This sensor can monitor for state of charge
threshold and notify the thermal framework.
If you want this support, you should say Y here.
config QTI_ADC_TM
tristate "Qualcomm Technologies Inc. Thermal Monitor ADC Driver"
depends on SPMI && THERMAL
depends on QCOM_SPMI_ADC5
help
This enables the thermal Sysfs driver for the ADC thermal monitoring
device. It shows up in Sysfs as a thermal zone with multiple trip points.
Thermal client sets threshold temperature for both warm and cool
and gets updated when a threshold is reached.
config QTI_CX_IPEAK_COOLING_DEVICE
bool "CX IPeak cooling device"
depends on THERMAL_OF
help
This implements a mitigation device to place a thermal client vote
to CXIP LM hardware. When all pre-defined clients on CX rail including
thermal client set their vote, CXIP LM hardware throttles the clients
on the CX rail.
If you want this support, you should say Y here.
config QTI_RPM_SMD_COOLING_DEVICE
bool "Qualcomm Technologies Inc. RPM SMD cooling device driver"
depends on MSM_RPM_SMD && THERMAL_OF
help
This implements a mitigation device to send temperature band
level to RPM hardware via SMD protocol. This mitigation device
will be used by temperature reliability rules to restrict a
railway at predefined voltage corner using RPM hardware.
If you want this support, you should say Y here.