ArmPlatformPkg/PL180MciDxe: update for identifying SD

When CMD6 & ACMD51 are added into identifying SD process, PL180
should also support CMD6 & ACMD51. Otherwise, it will hang when
system tries to read expected data.

Contributed-under: TianoCore Contribution Agreement 1.0
Signed-off-by: Haojian Zhuang <haojian.zhuang@linaro.org>
Reviewed-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Tested-by: Ryan Harkin <ryan.harkin@linaro.org>
diff --git a/ArmPlatformPkg/Drivers/PL180MciDxe/PL180Mci.c b/ArmPlatformPkg/Drivers/PL180MciDxe/PL180Mci.c
index 5526aac..f8e4cc0 100644
--- a/ArmPlatformPkg/Drivers/PL180MciDxe/PL180Mci.c
+++ b/ArmPlatformPkg/Drivers/PL180MciDxe/PL180Mci.c
@@ -63,11 +63,6 @@
   return (MmioRead32 (FixedPcdGet32 (PcdPL180SysMciRegAddress)) & SYS_MCI_WPROT);

 }

 

-#if 0

-//Note: This function has been commented out because it is not used yet.

-//      This function could be used to remove the hardcoded BlockLen used

-//      in MciPrepareDataPath

-

 // Convert block size to 2^n

 STATIC

 UINT32

@@ -87,7 +82,6 @@
 

   return Pow2BlockLen;

 }

-#endif

 

 VOID

 MciPrepareDataPath (

@@ -126,6 +120,23 @@
     MciPrepareDataPath (MCI_DATACTL_CARD_TO_CONT);

   } else if ((MmcCmd == MMC_CMD24) || (MmcCmd == MMC_CMD20)) {

     MciPrepareDataPath (MCI_DATACTL_CONT_TO_CARD);

+  } else if (MmcCmd == MMC_CMD6) {

+    MmioWrite32 (MCI_DATA_TIMER_REG, 0xFFFFFFF);

+    MmioWrite32 (MCI_DATA_LENGTH_REG, 64);

+#ifndef USE_STREAM

+    MmioWrite32 (MCI_DATA_CTL_REG, MCI_DATACTL_ENABLE | MCI_DATACTL_CARD_TO_CONT | GetPow2BlockLen (64));

+#else

+    MmioWrite32 (MCI_DATA_CTL_REG, MCI_DATACTL_ENABLE | MCI_DATACTL_CARD_TO_CONT | MCI_DATACTL_STREAM_TRANS);

+#endif

+  } else if (MmcCmd == MMC_ACMD51) {

+    MmioWrite32 (MCI_DATA_TIMER_REG, 0xFFFFFFF);

+    /* SCR register is 8 bytes long. */

+    MmioWrite32 (MCI_DATA_LENGTH_REG, 8);

+#ifndef USE_STREAM

+    MmioWrite32 (MCI_DATA_CTL_REG, MCI_DATACTL_ENABLE | MCI_DATACTL_CARD_TO_CONT | GetPow2BlockLen (8));

+#else

+    MmioWrite32 (MCI_DATA_CTL_REG, MCI_DATACTL_ENABLE | MCI_DATACTL_CARD_TO_CONT | MCI_DATACTL_STREAM_TRANS);

+#endif

   }

 

   // Create Command for PL180

@@ -223,7 +234,11 @@
 

   // Read data from the RX FIFO

   Loop   = 0;

-  Finish = MMCI0_BLOCKLEN / 4;

+  if (Length < MMCI0_BLOCKLEN) {

+    Finish = Length / 4;

+  } else {

+    Finish = MMCI0_BLOCKLEN / 4;

+  }

 

   // Raise the TPL at the highest level to disable Interrupts.

   Tpl = gBS->RaiseTPL (TPL_HIGH_LEVEL);