thermal: optimize trigger sensor settings

1. Reduce the polling time to 60s to reduce the lantancy when ThermalHAL
miss the trigger sensor's notification.
2. Adjust the trigger sensor's threshold to lower temperature.

Bug: 191971470
Bug: 191795038
Test: adb shell lshal debug android.hardware.thermal@2.0::IThermal/default

Change-Id: I2559944dfdef684ee93867a15dea257ee5f435b9
diff --git a/thermal_info_config_oriole.json b/thermal_info_config_oriole.json
index cd3449b..adac93d 100644
--- a/thermal_info_config_oriole.json
+++ b/thermal_info_config_oriole.json
@@ -134,7 +134,7 @@
             ],
             "VrThreshold":"NAN",
             "Multiplier":0.001,
-            "PollingDelay":300000,
+            "PollingDelay":60000,
             "PassiveDelay":7000
         },
         {
diff --git a/thermal_info_config_raven.json b/thermal_info_config_raven.json
index 054a42b..bbeb7a5 100644
--- a/thermal_info_config_raven.json
+++ b/thermal_info_config_raven.json
@@ -95,7 +95,7 @@
             "Type":"UNKNOWN",
             "HotThreshold":[
                 "NAN",
-                "34.2",
+                "32.2",
                 "NAN",
                 "NAN",
                 "NAN",
@@ -104,7 +104,7 @@
             ],
             "VrThreshold":"NAN",
             "Multiplier":0.001,
-            "PollingDelay":300000,
+            "PollingDelay":60000,
             "PassiveDelay":7000
         },
         {
@@ -273,7 +273,7 @@
                 1.9,
                 1.9,
                 1.9,
-                1.9,
+                1.4,
                 1.9,
                 1.9
             ],