| // SPDX-License-Identifier: GPL-2.0 | |
| /* | |
| * nvec_power: power supply driver for a NVIDIA compliant embedded controller | |
| * | |
| * Copyright (C) 2011 The AC100 Kernel Team <ac100@lists.launchpad.net> | |
| * | |
| * Authors: Ilya Petrov <ilya.muromec@gmail.com> | |
| * Marc Dietrich <marvin24@gmx.de> | |
| */ | |
| #include <linux/module.h> | |
| #include <linux/platform_device.h> | |
| #include <linux/err.h> | |
| #include <linux/power_supply.h> | |
| #include <linux/slab.h> | |
| #include <linux/workqueue.h> | |
| #include <linux/delay.h> | |
| #include "nvec.h" | |
| #define GET_SYSTEM_STATUS 0x00 | |
| struct nvec_power { | |
| struct notifier_block notifier; | |
| struct delayed_work poller; | |
| struct nvec_chip *nvec; | |
| int on; | |
| int bat_present; | |
| int bat_status; | |
| int bat_voltage_now; | |
| int bat_current_now; | |
| int bat_current_avg; | |
| int time_remain; | |
| int charge_full_design; | |
| int charge_last_full; | |
| int critical_capacity; | |
| int capacity_remain; | |
| int bat_temperature; | |
| int bat_cap; | |
| int bat_type_enum; | |
| char bat_manu[30]; | |
| char bat_model[30]; | |
| char bat_type[30]; | |
| }; | |
| enum { | |
| SLOT_STATUS, | |
| VOLTAGE, | |
| TIME_REMAINING, | |
| CURRENT, | |
| AVERAGE_CURRENT, | |
| AVERAGING_TIME_INTERVAL, | |
| CAPACITY_REMAINING, | |
| LAST_FULL_CHARGE_CAPACITY, | |
| DESIGN_CAPACITY, | |
| CRITICAL_CAPACITY, | |
| TEMPERATURE, | |
| MANUFACTURER, | |
| MODEL, | |
| TYPE, | |
| }; | |
| enum { | |
| AC, | |
| BAT, | |
| }; | |
| struct bat_response { | |
| u8 event_type; | |
| u8 length; | |
| u8 sub_type; | |
| u8 status; | |
| /* payload */ | |
| union { | |
| char plc[30]; | |
| u16 plu; | |
| s16 pls; | |
| }; | |
| }; | |
| static struct power_supply *nvec_bat_psy; | |
| static struct power_supply *nvec_psy; | |
| static int nvec_power_notifier(struct notifier_block *nb, | |
| unsigned long event_type, void *data) | |
| { | |
| struct nvec_power *power = | |
| container_of(nb, struct nvec_power, notifier); | |
| struct bat_response *res = data; | |
| if (event_type != NVEC_SYS) | |
| return NOTIFY_DONE; | |
| if (res->sub_type == 0) { | |
| if (power->on != res->plu) { | |
| power->on = res->plu; | |
| power_supply_changed(nvec_psy); | |
| } | |
| return NOTIFY_STOP; | |
| } | |
| return NOTIFY_OK; | |
| } | |
| static const int bat_init[] = { | |
| LAST_FULL_CHARGE_CAPACITY, DESIGN_CAPACITY, CRITICAL_CAPACITY, | |
| MANUFACTURER, MODEL, TYPE, | |
| }; | |
| static void get_bat_mfg_data(struct nvec_power *power) | |
| { | |
| int i; | |
| char buf[] = { NVEC_BAT, SLOT_STATUS }; | |
| for (i = 0; i < ARRAY_SIZE(bat_init); i++) { | |
| buf[1] = bat_init[i]; | |
| nvec_write_async(power->nvec, buf, 2); | |
| } | |
| } | |
| static int nvec_power_bat_notifier(struct notifier_block *nb, | |
| unsigned long event_type, void *data) | |
| { | |
| struct nvec_power *power = | |
| container_of(nb, struct nvec_power, notifier); | |
| struct bat_response *res = data; | |
| int status_changed = 0; | |
| if (event_type != NVEC_BAT) | |
| return NOTIFY_DONE; | |
| switch (res->sub_type) { | |
| case SLOT_STATUS: | |
| if (res->plc[0] & 1) { | |
| if (power->bat_present == 0) { | |
| status_changed = 1; | |
| get_bat_mfg_data(power); | |
| } | |
| power->bat_present = 1; | |
| switch ((res->plc[0] >> 1) & 3) { | |
| case 0: | |
| power->bat_status = | |
| POWER_SUPPLY_STATUS_NOT_CHARGING; | |
| break; | |
| case 1: | |
| power->bat_status = | |
| POWER_SUPPLY_STATUS_CHARGING; | |
| break; | |
| case 2: | |
| power->bat_status = | |
| POWER_SUPPLY_STATUS_DISCHARGING; | |
| break; | |
| default: | |
| power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN; | |
| } | |
| } else { | |
| if (power->bat_present == 1) | |
| status_changed = 1; | |
| power->bat_present = 0; | |
| power->bat_status = POWER_SUPPLY_STATUS_UNKNOWN; | |
| } | |
| power->bat_cap = res->plc[1]; | |
| if (status_changed) | |
| power_supply_changed(nvec_bat_psy); | |
| break; | |
| case VOLTAGE: | |
| power->bat_voltage_now = res->plu * 1000; | |
| break; | |
| case TIME_REMAINING: | |
| power->time_remain = res->plu * 3600; | |
| break; | |
| case CURRENT: | |
| power->bat_current_now = res->pls * 1000; | |
| break; | |
| case AVERAGE_CURRENT: | |
| power->bat_current_avg = res->pls * 1000; | |
| break; | |
| case CAPACITY_REMAINING: | |
| power->capacity_remain = res->plu * 1000; | |
| break; | |
| case LAST_FULL_CHARGE_CAPACITY: | |
| power->charge_last_full = res->plu * 1000; | |
| break; | |
| case DESIGN_CAPACITY: | |
| power->charge_full_design = res->plu * 1000; | |
| break; | |
| case CRITICAL_CAPACITY: | |
| power->critical_capacity = res->plu * 1000; | |
| break; | |
| case TEMPERATURE: | |
| power->bat_temperature = res->plu - 2732; | |
| break; | |
| case MANUFACTURER: | |
| memcpy(power->bat_manu, &res->plc, res->length - 2); | |
| power->bat_model[res->length - 2] = '\0'; | |
| break; | |
| case MODEL: | |
| memcpy(power->bat_model, &res->plc, res->length - 2); | |
| power->bat_model[res->length - 2] = '\0'; | |
| break; | |
| case TYPE: | |
| memcpy(power->bat_type, &res->plc, res->length - 2); | |
| power->bat_type[res->length - 2] = '\0'; | |
| /* | |
| * This differs a little from the spec fill in more if you find | |
| * some. | |
| */ | |
| if (!strncmp(power->bat_type, "Li", 30)) | |
| power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_LION; | |
| else | |
| power->bat_type_enum = POWER_SUPPLY_TECHNOLOGY_UNKNOWN; | |
| break; | |
| default: | |
| return NOTIFY_STOP; | |
| } | |
| return NOTIFY_STOP; | |
| } | |
| static int nvec_power_get_property(struct power_supply *psy, | |
| enum power_supply_property psp, | |
| union power_supply_propval *val) | |
| { | |
| struct nvec_power *power = dev_get_drvdata(psy->dev.parent); | |
| switch (psp) { | |
| case POWER_SUPPLY_PROP_ONLINE: | |
| val->intval = power->on; | |
| break; | |
| default: | |
| return -EINVAL; | |
| } | |
| return 0; | |
| } | |
| static int nvec_battery_get_property(struct power_supply *psy, | |
| enum power_supply_property psp, | |
| union power_supply_propval *val) | |
| { | |
| struct nvec_power *power = dev_get_drvdata(psy->dev.parent); | |
| switch (psp) { | |
| case POWER_SUPPLY_PROP_STATUS: | |
| val->intval = power->bat_status; | |
| break; | |
| case POWER_SUPPLY_PROP_CAPACITY: | |
| val->intval = power->bat_cap; | |
| break; | |
| case POWER_SUPPLY_PROP_PRESENT: | |
| val->intval = power->bat_present; | |
| break; | |
| case POWER_SUPPLY_PROP_VOLTAGE_NOW: | |
| val->intval = power->bat_voltage_now; | |
| break; | |
| case POWER_SUPPLY_PROP_CURRENT_NOW: | |
| val->intval = power->bat_current_now; | |
| break; | |
| case POWER_SUPPLY_PROP_CURRENT_AVG: | |
| val->intval = power->bat_current_avg; | |
| break; | |
| case POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW: | |
| val->intval = power->time_remain; | |
| break; | |
| case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN: | |
| val->intval = power->charge_full_design; | |
| break; | |
| case POWER_SUPPLY_PROP_CHARGE_FULL: | |
| val->intval = power->charge_last_full; | |
| break; | |
| case POWER_SUPPLY_PROP_CHARGE_EMPTY: | |
| val->intval = power->critical_capacity; | |
| break; | |
| case POWER_SUPPLY_PROP_CHARGE_NOW: | |
| val->intval = power->capacity_remain; | |
| break; | |
| case POWER_SUPPLY_PROP_TEMP: | |
| val->intval = power->bat_temperature; | |
| break; | |
| case POWER_SUPPLY_PROP_MANUFACTURER: | |
| val->strval = power->bat_manu; | |
| break; | |
| case POWER_SUPPLY_PROP_MODEL_NAME: | |
| val->strval = power->bat_model; | |
| break; | |
| case POWER_SUPPLY_PROP_TECHNOLOGY: | |
| val->intval = power->bat_type_enum; | |
| break; | |
| default: | |
| return -EINVAL; | |
| } | |
| return 0; | |
| } | |
| static enum power_supply_property nvec_power_props[] = { | |
| POWER_SUPPLY_PROP_ONLINE, | |
| }; | |
| static enum power_supply_property nvec_battery_props[] = { | |
| POWER_SUPPLY_PROP_STATUS, | |
| POWER_SUPPLY_PROP_PRESENT, | |
| POWER_SUPPLY_PROP_CAPACITY, | |
| POWER_SUPPLY_PROP_VOLTAGE_NOW, | |
| POWER_SUPPLY_PROP_CURRENT_NOW, | |
| #ifdef EC_FULL_DIAG | |
| POWER_SUPPLY_PROP_CURRENT_AVG, | |
| POWER_SUPPLY_PROP_TEMP, | |
| POWER_SUPPLY_PROP_TIME_TO_EMPTY_NOW, | |
| #endif | |
| POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN, | |
| POWER_SUPPLY_PROP_CHARGE_FULL, | |
| POWER_SUPPLY_PROP_CHARGE_EMPTY, | |
| POWER_SUPPLY_PROP_CHARGE_NOW, | |
| POWER_SUPPLY_PROP_MANUFACTURER, | |
| POWER_SUPPLY_PROP_MODEL_NAME, | |
| POWER_SUPPLY_PROP_TECHNOLOGY, | |
| }; | |
| static char *nvec_power_supplied_to[] = { | |
| "battery", | |
| }; | |
| static const struct power_supply_desc nvec_bat_psy_desc = { | |
| .name = "battery", | |
| .type = POWER_SUPPLY_TYPE_BATTERY, | |
| .properties = nvec_battery_props, | |
| .num_properties = ARRAY_SIZE(nvec_battery_props), | |
| .get_property = nvec_battery_get_property, | |
| }; | |
| static const struct power_supply_desc nvec_psy_desc = { | |
| .name = "ac", | |
| .type = POWER_SUPPLY_TYPE_MAINS, | |
| .properties = nvec_power_props, | |
| .num_properties = ARRAY_SIZE(nvec_power_props), | |
| .get_property = nvec_power_get_property, | |
| }; | |
| static int counter; | |
| static int const bat_iter[] = { | |
| SLOT_STATUS, VOLTAGE, CURRENT, CAPACITY_REMAINING, | |
| #ifdef EC_FULL_DIAG | |
| AVERAGE_CURRENT, TEMPERATURE, TIME_REMAINING, | |
| #endif | |
| }; | |
| static void nvec_power_poll(struct work_struct *work) | |
| { | |
| char buf[] = { NVEC_SYS, GET_SYSTEM_STATUS }; | |
| struct nvec_power *power = container_of(work, struct nvec_power, | |
| poller.work); | |
| if (counter >= ARRAY_SIZE(bat_iter)) | |
| counter = 0; | |
| /* AC status via sys req */ | |
| nvec_write_async(power->nvec, buf, 2); | |
| msleep(100); | |
| /* | |
| * Select a battery request function via round robin doing it all at | |
| * once seems to overload the power supply. | |
| */ | |
| buf[0] = NVEC_BAT; | |
| buf[1] = bat_iter[counter++]; | |
| nvec_write_async(power->nvec, buf, 2); | |
| schedule_delayed_work(to_delayed_work(work), msecs_to_jiffies(5000)); | |
| }; | |
| static int nvec_power_probe(struct platform_device *pdev) | |
| { | |
| struct power_supply **psy; | |
| const struct power_supply_desc *psy_desc; | |
| struct nvec_power *power; | |
| struct nvec_chip *nvec = dev_get_drvdata(pdev->dev.parent); | |
| struct power_supply_config psy_cfg = {}; | |
| power = devm_kzalloc(&pdev->dev, sizeof(struct nvec_power), GFP_NOWAIT); | |
| if (!power) | |
| return -ENOMEM; | |
| dev_set_drvdata(&pdev->dev, power); | |
| power->nvec = nvec; | |
| switch (pdev->id) { | |
| case AC: | |
| psy = &nvec_psy; | |
| psy_desc = &nvec_psy_desc; | |
| psy_cfg.supplied_to = nvec_power_supplied_to; | |
| psy_cfg.num_supplicants = ARRAY_SIZE(nvec_power_supplied_to); | |
| power->notifier.notifier_call = nvec_power_notifier; | |
| INIT_DELAYED_WORK(&power->poller, nvec_power_poll); | |
| schedule_delayed_work(&power->poller, msecs_to_jiffies(5000)); | |
| break; | |
| case BAT: | |
| psy = &nvec_bat_psy; | |
| psy_desc = &nvec_bat_psy_desc; | |
| power->notifier.notifier_call = nvec_power_bat_notifier; | |
| break; | |
| default: | |
| return -ENODEV; | |
| } | |
| nvec_register_notifier(nvec, &power->notifier, NVEC_SYS); | |
| if (pdev->id == BAT) | |
| get_bat_mfg_data(power); | |
| *psy = power_supply_register(&pdev->dev, psy_desc, &psy_cfg); | |
| return PTR_ERR_OR_ZERO(*psy); | |
| } | |
| static int nvec_power_remove(struct platform_device *pdev) | |
| { | |
| struct nvec_power *power = platform_get_drvdata(pdev); | |
| cancel_delayed_work_sync(&power->poller); | |
| nvec_unregister_notifier(power->nvec, &power->notifier); | |
| switch (pdev->id) { | |
| case AC: | |
| power_supply_unregister(nvec_psy); | |
| break; | |
| case BAT: | |
| power_supply_unregister(nvec_bat_psy); | |
| } | |
| return 0; | |
| } | |
| static struct platform_driver nvec_power_driver = { | |
| .probe = nvec_power_probe, | |
| .remove = nvec_power_remove, | |
| .driver = { | |
| .name = "nvec-power", | |
| } | |
| }; | |
| module_platform_driver(nvec_power_driver); | |
| MODULE_AUTHOR("Ilya Petrov <ilya.muromec@gmail.com>"); | |
| MODULE_LICENSE("GPL"); | |
| MODULE_DESCRIPTION("NVEC battery and AC driver"); | |
| MODULE_ALIAS("platform:nvec-power"); |