Revert notification patterns to default pre-S ones [DO NOT MERGE]
Bug: 210535717
Test: manual
Change-Id: I6ead011f1cc28ea0c061941ab1665ed8250c3784
(cherry picked from commit ba9024c7802357ae2da0b6ae6a9d889544611f03)
Merged-In: I6ead011f1cc28ea0c061941ab1665ed8250c3784
diff --git a/oriole/overlay/frameworks/base/core/res/res/values/config.xml b/oriole/overlay/frameworks/base/core/res/res/values/config.xml
index cf57ec0..f2bc440 100644
--- a/oriole/overlay/frameworks/base/core/res/res/values/config.xml
+++ b/oriole/overlay/frameworks/base/core/res/res/values/config.xml
@@ -227,88 +227,6 @@
non-zero amplitudes, to bring the vibrator amplitude down to zero using this timing. -->
<integer name="config_vibrationWaveformRampDownDuration">50</integer>
- <!-- A vibration waveform for notifications that specify DEFAULT_VIBRATE.
- This value is a float array with values grouped as
- { targetAmplitude (within [0,1]), targetFrequency [-1,1], duration (in milliseconds) }
- This is only applied on devices with vibration frequency control. If the device doesn't
- support frequency control, then the vibration specified in
- config_defaultNotificationVibePattern is used instead.
- -->
- <array name="config_defaultNotificationVibeWaveform">
- <item>0.0</item>
- <item>-0.85</item>
- <item>0.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>100.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>100.0</item>
- </array>
-
- <!-- A vibration waveform for notifications that do not specify vibration but vibrate anyway,
- because the device is in vibrate mode. This value is a float array with values grouped as
- { targetAmplitude (within [0,1]), targetFrequency [-1,1], duration (in milliseconds) }
- This is only applied on devices with vibration frequency control. If the device doesn't
- support frequency control, then the vibration specified in
- config_notificationFallbackVibePattern is used instead.
- -->
- <array name="config_notificationFallbackVibeWaveform">
- <item>0.0</item>
- <item>-0.85</item>
- <item>0.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>50.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>50.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>100.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>50.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>50.0</item>
- </array>
-
<!-- the number of the max cached processes in the system. -->
<integer name="config_customizedMaxCachedProcesses">64</integer>
</resources>
diff --git a/raven/overlay/frameworks/base/core/res/res/values/config.xml b/raven/overlay/frameworks/base/core/res/res/values/config.xml
index 491a4cc..7da850b 100644
--- a/raven/overlay/frameworks/base/core/res/res/values/config.xml
+++ b/raven/overlay/frameworks/base/core/res/res/values/config.xml
@@ -195,88 +195,6 @@
non-zero amplitudes, to bring the vibrator amplitude down to zero using this timing. -->
<integer name="config_vibrationWaveformRampDownDuration">50</integer>
- <!-- A vibration waveform for notifications that specify DEFAULT_VIBRATE.
- This value is a float array with values grouped as
- { targetAmplitude (within [0,1]), targetFrequency [-1,1], duration (in milliseconds) }
- This is only applied on devices with vibration frequency control. If the device doesn't
- support frequency control, then the vibration specified in
- config_defaultNotificationVibePattern is used instead.
- -->
- <array name="config_defaultNotificationVibeWaveform">
- <item>0.0</item>
- <item>-0.85</item>
- <item>0.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>100.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>100.0</item>
- </array>
-
- <!-- A vibration waveform for notifications that do not specify vibration but vibrate anyway,
- because the device is in vibrate mode. This value is a float array with values grouped as
- { targetAmplitude (within [0,1]), targetFrequency [-1,1], duration (in milliseconds) }
- This is only applied on devices with vibration frequency control. If the device doesn't
- support frequency control, then the vibration specified in
- config_notificationFallbackVibePattern is used instead.
- -->
- <array name="config_notificationFallbackVibeWaveform">
- <item>0.0</item>
- <item>-0.85</item>
- <item>0.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>50.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>50.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>100.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>50.0</item>
-
- <item>0.4</item>
- <item>-0.25</item>
- <item>100.0</item>
-
- <item>0.0</item>
- <item>-0.85</item>
- <item>50.0</item>
- </array>
-
<!-- Height of the status bar.